Process Technology

Wet Process Heating and Cooling Equipment

DQ Series, Digital Combination Controls

MODEL
NUMBER

VOLTS

MAX.
AMPS
REPL.
RELAY P/N
REPL.
RELAY P/N
LESS TRANS.
REPL.
TRANS.
REPL.
SENSOR P/N

SHIP WGT.
Lbs./(kg)

DQ302 240 30 AH30-1 AH30-2 HD50 2/1 RTD1000 16 (7.5)
DQ304 480 30 AH30-l   HD50 4/1 RTD1000 16 (7.5)
DQ502 240 50 AH50-1 AH50-2 HD50 2/1 RTD1000 17 (8)
DQ504 480 50 AH50-1   HD50 4/1 RTD1000 17 (8)
DQ752 240 75 AH75-1 AH75-2 HD100 2/1 RTD1000 23 (10.5)
DQ754 480 75 AH75-1   HD100 4/1 RTD1000 23 (10.5)
DQ902 240 90 AH90-1 AH90-2 HD100 2/1 RTD1000 25 (11.5)
DQ904 480 90 AH90-1   HD100 4/1 RTD1000 25 (11.5)
DQ1202 240 120 AH120-1 AH120-2 HD150 2/1 RTD1000 27 (12.5)
DQ1204 480 120 AH120-1   HD150 4/1 RTD1000 27 (12.5)
DQ1502 240 150 AH150-1 AH150-2 HD150 2/1 RTD1000 33 (15)
DQ1504 480 150 AH150-1   HD150 4/1 RTD1000 33 (15)

Combination control consists of gasketed plastic enclosure, thermostat, contactor and optional control transformer. To omit step-down transformer, add "LT" to end of model number.  
**
Thermal Protection Systems

Product Features and Benefits:

IMPROVES PROCESS CONTROL: Large (.56" high), easy to read LED display. Two set points (heating and cooling). Provides precise control for consistent plating and etch rates in most aqueous processes.

TEMPERATURE SENSOR: Fluoropolymer (FEP) covered 10-foot (3m), 1000-ohm platinum RTD sensor included standard with the control. Provides extended service in corrosive liquids and can be lengthened with ordinary copper hookup wire.

CORROSION RESISTANT ENCLOSURE: NEMA 1, IP23, gasketed plastic enclosure with sealed tactile switches and stainless steel hardware.

CERTIFICATIONS: cUL.

CAPACITIES:

Large switching capacities from 30 to 150 amps for either 240 or 480 volts (other voltages available).
Single pole, double throw switch rated at 2 amps for cooling loads.
Adjustable temperature range from -40°F (-40°C) to 999°F (538°C).
+/- .25% full span, single digit accuracy.
20°F (-7°C) to 130°F (54°C) ambient temperature range.
Programmable standby temperature setting for overnight control and energy savings.
120, 208, 380, 415, 600 and other voltages available.

Single or three phase.

Control transformer required above 240 volts and recommended for 208 and 240 volt service.

SAFETY FEATURES:

Pre-wired P1 terminal blocks.
Non-volatile memory.
Programmable high alarm shutdown.
Sensor short and break protection.
Programmable high setpoint limit.
Security code restricted menu.

OPTIONS AVAILABLE (consult factory):

25-foot (7.6m) and 50-foot (15.2m) sensors.
Pre-wired outlets for plug-in heaters (some sizes).
Ground fault protection (GFP) circuitry.
P2 or P3 thermal protection systems.
Integral liquid level control components.
Front panel mounted digital timers.
Three wire 100-ohm RTD sensors.
Type J, K, T, and R thermocouples.

Special sensors. Required for temperatures above 500°F (260°C).

Scalable voltage and current inputs.
4-20 mA outputs for process recording.
CE compliance.
Outdoor enclosures.

DOWNLOAD THE INFORMATION SHEET (including dimensional diagram)

[ Home | Search our Site | Industrial Products | Aquaculture Products ]
[
High Purity Products | Product Specials | Company Profile ]
[ Trade Shows | What's New | Employment Opportunities ]
[ Troubleshooting Guide | PDF Files | Contact Us ]

Copyright © 2012 Process Technology
info@process-technology.com