| MODEL NUMBER | VOLTS (See Thermal Overload Protection) |
MAX. AMPS | REPL. RELAY P/N | REPL. RELAY P/N (LESS TRANS.) |
REPL. TRANS. P/N | REPL. SENSORS | SHIP WGT. Lbs./(kg) |
|---|---|---|---|---|---|---|---|
| DSL302 | 240 | 30 | AH30-1 | AH30-2 | HD50 2/1 | RTD1000 | 16 (7.5) |
| DSL304 | 480 | 30 | AH30-1 | HD50 4/1 | RTD1000 | 16 (7.5) | |
| DSL502 | 240 | 50 | AH50-1 | AH50-2 | HD50 2/1 | RTD1000 | 17 (8) |
| DSL504 | 480 | 50 | AH50-1 | HD50 4/1 | RTD1000 | 17 (8) | |
| DSL752 | 240 | 75 | AH75-1 | AH75-2 | HD100 2/1 | RTD1000 | 23 (10.5) |
| DSL754 | 480 | 75 | AH75-1 | HD100 4/1 | RTD1000 | 23 (10.5) | |
| DSL902 | 240 | 90 | AH90-1 | AH90-2 | HD100 2/1 | RTD1000 | 25 (11.5) |
| DSL904 | 480 | 90 | AH90-1 | HD100 4/1 | RTD1000 | 25 (11.5) | |
| DSL1202 | 240 | 120 | AH120-1 | AH120-2 | HD100 2/1 | RTD1000 | 27 (12.5) |
| DSL1204 | 480 | 120 | AH120-1 | HD100 4/1 | RTD1000 | 27 (12.5) | |
| DSL1502 | 240 | 150 | AH150-1 | AH150-2 | HD150 2/1 | RTD1000 | 33 (15) |
| DSL1504 | 480 | 150 | AH150-1 | HD150 4/1 | RTD1000 | 33 (15) | |
| Combination
control consists of gasketed plastic enclosure, thermostat, contactor and optional control
transformer. To omit step-down transformer, add "LT" to end of model number. ** Thermal Protection Systems |
|||||||
Product Features and Benefits:
IMPROVES PROCESS CONTROL: Easy to read dual LED displays (.3 inches high). Two set points (heating and cooling). Provides precise control for consistent plating and etch rates in most aqueous processes.
TEMPERATURE SENSOR: Fluoropolymer (FEP) covered 10-foot (3m), 1000-ohm platinum RTD sensor included standard with the control. Provides extended service in corrosive liquids and can be lengthened with ordinary copper hookup wire.
CORROSION RESISTANT ENCLOSURE: NEMA 1, IP23, gasketed plastic enclosure with sealed tactile switches and stainless steel hardware.
CERTIFICATIONS: cUL.
CAPACITIES:
Large switching capacities from 30 to 150 amps for either 240 or 480 volts (other voltages available). Single pole single-throw switch rated at 3 amps for cooling loads. Adjustable temperature range from -328°F (-200°C) to 4208°F (2320°C). +/- .25% full span, single digit accuracy. 20°F (-7°C) to 130°F (54°C) ambient temperature range. 120, 208, 380, 415, 600 and other voltages available. Single or three phase. Control transformer required above 240 volts and recommended for 208 and 240 volt service.
SPECIAL FEATURES: Auto tune PID, PID or On/Off control with Auto/Manual operation.
SAFETY FEATURES:
Pre-wired P1 terminal blocks. Non-volatile memory. Programmable high alarm shutdown. Sensor short and break protection. Programmable high setpoint limit. Security code restricted menu. OPTIONS AVAILABLE (consult factory):
25-foot (7.6m) and 50-foot (15.2m) sensors. Pre-wired outlets for plug-in heaters (some sizes). Ground fault protection (GFP) circuitry. P2 or P3 thermal protection systems. Integral liquid level control components. Front panel mounted digital timers. Three wire 100-ohm RTD sensors. Type J, K, T, and R thermocouples. Special sensors. Required for temperatures above 500°F (260°C). Scalable voltage and current inputs. 4-20 mA or 0-10VDC outputs for process recording. 4-20 mA or 15VDC control outputs. Voltage, relay, logic/SSR and current outputs. RS232 or RS485 communication protocol. CE compliance. Outdoor enclosures. DOWNLOAD THE INFORMATION SHEET (including dimensional diagram)
[ Home | Search
our Site | Industrial Products | Aquaculture
Products ]
[ High Purity Products | Product Specials | Company Profile ]
[ Trade Shows | What's New | Employment Opportunities ]
[ Troubleshooting Guide | PDF
Files | Contact Us ]
Copyright © 2012
Process Technology
info@process-technology.com